KINGSPAN K18 PDF

Kooltherm K18 Insulated Plasterboard is a super high performance insulated dry- lining plasterboard suitable for mechanical fixing. Buy mm Kingspan Kooltherm K18 Insulated Plasterboard, a premium performance fibre-free rigid thermoset phenolic insulation core bonded to mm. Kingspan Kooltherm K18 Insulated Plasterboard is a premium performance insulation, with a fibre-free rigid thermoset phenolic insulation core with mm .

Author: Dair Tegrel
Country: Tajikistan
Language: English (Spanish)
Genre: Science
Published (Last): 10 June 2008
Pages: 48
PDF File Size: 4.95 Mb
ePub File Size: 14.96 Mb
ISBN: 516-9-53434-224-9
Downloads: 67997
Price: Free* [*Free Regsitration Required]
Uploader: Shaktijora

Customer Review Write an online review and share your thoughts with other shoppers! Finishing Tapered edged boards allow the employment of standard dry—lining techniques. This method is for application to fair finished brick, block and concrete cavity walls where K18 Insulated Wallboard is to be finished with gypsum plaster.

Click Tick-Box to select one or more items. The insulation core and facings used in the manufacture of K18 Insulated Plaster Board resist attack by mould and microbial growth and do not provide any food value to vermin. However, short lead times may apply.

Cutting Cutting should be carried out either by using a fine toothed saw, or by scoring with a sharp knife, snapping the board over a straight edge and then cutting the facing on the other side.

Kingspan Insulation – Kooltherm K18 Insulated Plasterboard

Resistance to Solvents The insulation core is resistant to short-term contact with petrol and with most dilute acids, alkalis and mineral oils. Test – BS —6: The contribution of the product Total R-values depends on installation and environmental conditions.

Celotex PL range, Plasterboard Backed. Method of test for fire propagation for products Result – Fire propagation index of Fire tests on k8 performance 1 not exceeding 12 and sub Index i1 not exceeding 6 for rigid phenolic insulation core Test – BS —7: Cutting should be carried out either by using a fine toothed saw, or by scoring with a sharp knife, snapping the board over a straight edge and then cutting the facing on the other side.

  BARTOK DIVERTIMENTO PARTS PDF

Care should be taken not to overdrive the fixing. They should be driven straight with the heads embedded just below the surface of the board.

52.5mm Kingspan Kooltherm K18 Insulated Plasterboard – pack of 15

On existing constructions all surfaces should be clean and free of loose or flaking materials. K 25—44 mm 0. Fixings should not overlap board edges. We use cookies on our website www. Kooltherm K18 combines insulation, dry—lining and vapour control in one board. Specifications Useful links Case Studies.

Kooltherm K18 Insulated Plasterboard | Kingspan | Australia

Kooltherm K18 combines insulation, dry—lining and vapour control in one board Kingspan K18 Board Sizes and Values Available in in the standard size of mm wide by mm long, and in the following thicknesses The screws should be driven straight until the heads are slightly below the paper surface of the plasterboard facing.

This method may be used on timber frame, metal stud and track constructions or on kingspa dry masonry walls that will support and retain the battens and associated fixings. Shopping Your basket is empty. This method may be used on timber frame constructions or on any dry masonry walls that will support and retain the battens and associated fixings.

Kingspam to Solvents The insulation core is resistant to short-term contact with petrol and with most dilute acids, alkalis and mineral oils. Method of test to determine the classification of the surface spread of flame of products.

If correctly applied, K18 Insulated Wall Board has an indefinite life.

For any enquiries, call or send an email to info kingspaninsulation. Method of test to determine the classification of the surface spread of flame of products Result – Class 1 rating. Wall mounted fittings such as electrical sockets should be fitted so as to take into account the additional wall thickness.

Boards must always be placed with the long edge running across the joists, rafters or battens and all edges must be supported. The wall should be sound, dry and level as surface irregularities may impede fixing of the board.

  JEREMY RIFKIN EUROPEJSKIE MARZENIE PDF

Installation is similar to that of standard plasterboard. Please note that the reflective surfaces on this product are designed to enhance their thermal performance. The R-value will be reduced in the event of the accumulation of dust on the upward facing surfaces and in those cavities that are ventilated.

UK cheap wall Insulation Specialists : Kingspan Insulation : Celotex Insualtion

This product is a mechanical fix product and as such is most lingspan erected kingsspan battens. The ceiling lining should be in position before wall lining commences. Pricing and Where to Buy. Boards must always be placed with the long edge running across the joists, rafters or battens and all edges must be supported. Care should be taken to ensure that the cavity in cavity wall constructions is not bridged by the board or fixing medium in such a manner that would allow the passage of water through to the inner leaf.

Do you need help and advice on your project? It should, therefore, not be used to isolate dampness nor be used in continuously damp or humid conditions. Cutting Cutting should be carried out either by using a fine toothed saw, or by scoring with a sharp knife, snapping the board over a straight edge and then cutting the facing on the other side.

Finishing Tapered edged boards allow the employment of standard dry—lining techniques. Adhesives containing such solvents should not be used in association with this product.

Boards should be stored inside a building. Boards should be stored inside a building. This reflective, low emissivity surface improves the thermal resistance of any unventilated cavity adjacent to the K Timbers should be treated where appropriate.